120 Man – Modular Offshore Living Quarters

Product details below

Contact us for current pricing and availability.

Category:

Description

Modular Offshore Living Quarters

BASE SCOPE OF WORK

PROJECT SUMMARY: Supply as is / where is 120 Man Offshore Living Quarters

Level-1 Total of 6-Modules 10′ x 40′ x 11’6” Nominal Height; 0-Men
Module A01 – (2) Fresh Water Tanks 145 bbls. Each with Water Makers
Module A02 – Fresh Water Tank 465 bbls. With (2) Pressure Sets
Module A03 – Electrical Room
Module A04 – Storage Room & Locker Room
Module A05 – Laundry / Community Restrooms
Module A06 – Conference & Recreation Room

Level-2 Total of 6-Modules 10′ x 40′ x 11’6” Nominal Height; 4-Men
Module A07 – Dry Storage & 4-Man Sleeper
Module A08 – Freezer & Cooler
Module A09 – Galley & Serving
Module A10 – Dining Room # 1 (48 Man Sitting Area Total Both Dining)
Module A11 – Dining Room # 2
Module A12 – Medic Office & Treatment Room

Level-3 Total of 6-Modules 10′ x 40′ x 11’6” Nominal Height; 48-Men
Module A13 – 8-Man Sleeper
Module A14 – 8-Man Sleeper
Module A15 – 8-Man Sleeper
Module A16 – 8-Man Sleeper
Module A17 – 8-Man Sleeper
Module A18 – 8-Man Sleeper

Level-4 Total of 6-Modules 10′ x 40′ x 11’6” Nominal Height; 48-Men
Module A19 – 8-Man Sleeper
Module A20 – 8-Man Sleeper
Module A21 – 8-Man Sleeper
Module A22 – 8-Man Sleeper
Module A23 – 8-Man Sleeper
Module A24 – 8-Man Sleeper

Level-5 Total of 6-Modules 10′ x 40′ x 11’6” Nominal Height; 20-Men
Module A25 – Radio Room & 4-Man Sleeper w/Bathroom
Module A26 – Office & 1-Man Sleeper w/Bathroom
Module A27 – Office & 2-Man Sleeper w/Bathroom
Module A28 – Office & 1-Man Sleeper w/Bathroom
Module A29 – 4-Man & 4-Man Sleeper w/Bathroom
Module A30 – 4-Man & 4-Man Sleeper w/Bathroom

Fabrication:
Fabrication and outfitting to be performed to meet supplied drawings. All materials and equipment, fixtures, appliances and furniture shall be new and free of defect.
Fabrication shall be per below listed details.

1. Codes and Standards
a. API-RP 2A, WSD, 21st Edition, Dec 2000
b. AISC-ASD, 9th Edition, June 1, 1989
c. AWS-D1.1:M2010
d. IMO 844E
e. OSHA

2. Architectural
a. Walls:
The interior bulkheads shall be constructed using Isonell interlocking panels A-60 2560 X 555 X 100mm; Color to be selected by client; MED 2014/90/EU QUALITY SYSTEM
MODULE D CERTIFICATE Bureau Veritas
b. Flooring:
Steel deck to be prepped and primed Ameron PPG Coatings. Epoxy Floor System;
custom color sand, flexible seamless epoxy flooring system.
c. Ceiling:
Shall be constructed using 2′ x 2’Armstrong Prelud3e XL Grid system with 2’ x 2’ Armstrong Fine Fissured Tiles installed in the grid.
d. Insulation:
Insulation shall be Delta Marine board, or Firemaster Marine plus Blanket secured with weld pins and washers, celling and floors, interior/exterior walls Isonell interlocking
panels A-60 2560 X 555 X 100mm. Insulation in floor is sealed with 10-gauge belly pan seal welded.
e. Doors
1. Interior: A-60 Rated, B-15 Rated, or C Class as per Door Schedule
2. Exterior: A60 Rated; as per Door Schedule
f. Windows
1. Exterior: A-60 Rated; as per Window Schedule

3. Structural (Steel Fabrication)
a. Exterior wall panels shall be crimped; 3/16” thick steel plate as per drawing requirements.
b. Wide Flange Steel Skid Members.
c. ¼” steel plate for floor included.
d. Tubular framing structural members for exterior walls with ISO connectors located at each corner.
e. Steel roof and floor joists framing members.
f. Lifting eyes in Module roof framing pull tested w/ post pull NDE.
g. All welded construction as per AWS D1.1

4. Helideck
a. Quote provided under other job number

5. Electrical
A. Lighting System
1. Interior
a. 2’x4′ Fluorescent Lay-in fixtures, 2x32w T8 lamps, electronic ballast,120/277V (Qty. As required)
b. 2’x2′ Fluorescent Lay-in fixtures, 2x32w T8 lamps, electronic ballast,120/277V (Qty. As required)
c. 18″ Fluorescent Bunk lights, 1x15W T8 Lamp, electronic ballast
d. LED Exit lights with 90 min battery backup Simkar SLED Series
e. Emergency Lights wired into customer supplied battery rated for 18 hr power supply
2. Exterior Lighting: a. LED, 120V Class 1, Div 2 marine type, to be installed on each main exit door.
3. Exterior Junction Boxes: i. NEMA 4X SS JB

B. Switches and Receptacles
1. 20A, 120V Duplex Receptacles industrial grade (Qty. to be supplied as required)
2. 20A, 120V GFI Duplex Receptacles industrial grade to be installed in wet area locations such as: bathrooms, galley and laundry
3. 20A, 120V, Single and 3w switches (Qty. to be supplied as required)

C. Distribution Panels
1. Each building must have a lighting panel with MCB different sizes based on the load per building, the panels shall be 1 ph, 208/120V, 60Hz.
2. Galley Module shall have a 200A, 3PH, 4w Panel board
3. Laundry Modules shall have a 150A, 3PH, 4w Panel board

D. Main Electrical Distribution Equipment:
1. (1) 800A, MCB, 600V, 3PH NEMA 1 Distribution Panelboard
2. (1) 400A, MCB, 480V, 3PH NEMA 1 Distribution Panelboard
3. (2) 800AF/650AT, MCB, 208/120VAC, 3PH, 4W NEMA 1 Distribution Panelboards
4. (1) 225KVA, 600/480V, 60Hz, 3Ph. Distribution Transformer
5. (2) 225KVA, 600/208-120VAC, 3PH NEMA 1 Distribution Transformers
6. (1) 75KVA, 480/208-120VAC, 3PH NEMA 3R Distribution Transformer
7. (1) 208/120VAC Plug board with Power receptacles and Plugs Installed
8. (1) 600VAC Plug board with Power receptacles

6. Fire and Gas Detection System

Equipment Installation, Termination, and Commissioning provided by LSEF. Living Quarters
Includes the following F&G Devices:
• Sensepoint CH4 Gas Detectors
• Sensepoint H2S Gas Detectors
• Autronica Smoke Detectors
• Autronica Flame Detector
• Autronica Heat Detector
• Autronica Manual Call Point
• Jelec General Alarm Strobes
• Jelec Manual Pull Stations
• F&G, CPU Cabinet

7. Fire-Fighting System
a. Dry Chemical Powder Extinguishers (minimum of 10 lb or 20 lb as req)
b. CO2 Extinguishers (as req)
c. ANSUL System in Galley
d. FM 200 Suppression system in Radio room and Electrical room

8. Paging System
Equipment Installation, Termination, and Commissioning provided by LSEF.
The Living Quarters includes the following PAGA equipment:
DHT Indoor Speaker
DHT Weather Proof Speakers
CISCO Desktop IP Phone
Soundstation Conference Call Phone
PAGA Access Station
PAGA System 19 Rack Cabinet

9. Voice, Data, TV, Intercom, Music, Telephone, WiMax, CCTV, and UPS
Voice, Data, TV, Intercom, Music, Telephone, WiMax, and CCTV.
The LQ includes the following Communication equipment:
• AXIS POE Indoor PTZ Dome Camera
• RJ45 Wall Sockets
• TV Coaxial Connection
• Wireless Base Station (WiFi)
• Weather Minitoring Station
• Voice & Data system termination cabinet
• WIMAX /Satellite Cabinet

Electrical Note:
All Indoor and outdoor electrical cabling shall be Marine P-Type

10. Mechanical – HVAC
a. General Sleeper Modules; Mini Split-Units; Multi Zone; 36,000 BTUs
b. Galley Module; Mini-Split Units; Dual Zone; 36,000 BTUs
c. Laundry Module: Mini-Split Units; Dual Zone; 36,000 BTUs
d. 4-Men and Office Module; Mini-Split Units; Multi Zone; 36,000 BTUs
e. HVAC units are ductless; air Handlers shall be installed in their respective rooms
f. Compressor Unit Shall be installed the module exteriors as per drawings
g. HVAC are Non-Classified

11. Plumbing
a. Black & Gray Sanitary Drain Line: Schedule 80 steel – Exterior of module
b. Black & Gray Drain lines: PVC Schedule 80 – Interior
c. Interconnection Sanitary Piping at ends of modules: Schedule 80 PVC
d. Potable Water: copper – Interior
e. Interconnection Potable Water Piping at ends of modules: Reinforced poly tubing
f. Toilet salt water flush piping: CPVC – Interior
g. Interconnection Salt Water Piping at ends of modules: Reinforced poly tubing
h. Floor drains where required
i. Fixtures:
1. Toilets: complete with flush valves and partition as per drawings and hand bidet
2. Sinks: complete with fixtures
3. State Water Heaters – as per drawings
4. Showers – complete with fixtures

12. Auxiliary Equipment
a. (2) 60m3 H2O Water Makers
b. (2) Pressure Sets for Potable Water Supply
Note: Service and Transfer Pumps, are not included

13. Coating System
a. Steel shall be blasted to a near white immediately prior to application of primer
b. Exterior Coating: Painted with three coat epoxy and urethane system for offshore service.
c. Interior: Primer – 5 mills epoxy

14. Other
a. Office, Recreation Room Furniture, Washer/Dryers, Galley Equipment, Serving Tables, Refreshment Dispensers, Water Heaters, Lockers, Bunk Beds, and Mattresses shall be furnished per drawings.
b. Audible Freezer/Cooler Man Trapped Alarm.

15. Exclusions:
a. Emergency Generator (supplied by others)
b. Deep well pump or salt water supply (supplied by others)
c. Helideck, support structure and means of access (see quote #2798-22A)
d. Transportation
e. Access Control other than Keyed Locks on Office Doors
f. Linens, Misc. Galley/Dining Utensils, and Medical Instruments